| Customization: | Available |
|---|---|
| Warranty: | One Year |
| Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency





| model item | XJY-50 | XJY-100 | XJY-200 |
| Incineration capacity | 30-50 k |
50-100 kg |
150-200 kg |
| size(L×B×H) (m) |
1.45×0.9×2.75 | 1.8×1.15×3 | 2×1.4×3.5 |
| Input port size (mm) |
480×600 | 620×800 | 760×960 |
| Chimney size (mm) |
Outside diameter ø280 | Outside diameter 280 | Outside diameter ø300 |
| The power of the fan | 0.25kw | 0.25kw | 0.55kw |
| Combustion burner | Power 0.15kw Fuel consumption 4-6kg/h |
Power 0.15kw 4-10kg/h |
Power 0.15kw 4-10kg/h |
Reburning burner |
Power 0.15kw Fuel consumption 4-6kg/h |
0.15kw 4-10kg/h |
0.37kw 7-10kg/h |
Voltage |
380V or 220V | 380V or 220V | 380V or 220V |
| Weight(kg) | 4000 | 5000 | 8000 |
| model item | XJY-300 | XJY-400 | XJY-500 |
| Incineration capacity | 200-300kg |
300-400kg |
400-500kg |
| size(L×B×H) (m) |
2.2×1.4×3.8 | 3×2×4.8 | 3.3×2.3×4.8 |
| Input port size (mm) |
900×1100 | 1080×1280 | 1400×1300 |
| Chimney size (mm) |
Outside diameter ø400 |
ø460 | ø480 |
| The power of the fan | 0.75kw | 0.75kw | 1.1kw |
| Combustion burner | Power 0.15kw Fuel consumption 7-10kg/h |
0.37kw 7-14kg/h |
0.37kw 7-14kg/h |
Reburning burner |
Power 0.37kw Fuel consumption 10-20kg/h |
0.37kw 15-26kg/h |
0.37kw 15-26kg/h |
| Voltage | 380V or 220V | 380V or 220V | 380V or 220V |
| Weight(kg) | 9000 | 16500 | 20000 |
| The types of wastes |
The incineration temperature (ºC) |
Flue gas residence time (S) |
The incineration efficiency (%) |
The incineration residue heat ignition loss rate (%) |
Hospital clinical waste |
≥850 | ≥2.0 | ≥99 | ≥5 |
Serial number |
Pollutants. | The unit of measurement |
GB18484-2001 |
| 1 | The blackness | mg/m | 1 |
| 2 | Smoke and dust | mg/m | 100 |
| 3 | CO | mg/m | 100 |
| 4 | SO2 | mg/m | 200 |
| 5 | HF | mg/m | 9.0 |
| 6 | HCL | mg/m | 100 |
| 7 | NO2 | mg/m | 500 |